Voltage |
|
Range |
5V, 10V, 20V, 40V,
80V, 160V, 320V, 640V total 8 ranges by auto-range or manual |
|
Measurement Type |
True rms |
|
Input Resistance |
>1MΩ |
|
Max. Input Voltage |
1000V (peak), 700V
(rms) |
|
PT Ratio Setting |
1 ~ 9999 |
Accuracy (at 23°C+5°C)
(Sinewave) |
+
0.1% of reading + 0.1% of range |
|
|
Current |
|
Range |
160mA, 320mA,
640mA, 1.280A, 2.560A, 5.120A, 10.24A, 20.48A total 8 ranges by auto-range
or manual |
|
Measurement Type |
True rms |
|
Input Resistance |
0.01Ω |
|
Max. Input Current |
30A (peak), 20A (rms) |
|
CT Ratio Setting |
1 ~ 9999 |
Accuracy (at 23°C+5°C)
(Sinewave) |
+
0.1% of reading + 0.1% of range |
|
|
Watt |
|
Measurement Range |
0.32mW ~13.10kW |
|
Measurement Type |
True rms |
Accuracy (at 23°C+5°C)
(Sinewave) |
+
0.2% of reading + 0.2% of range |
|
|
Power Factor |
|
Range |
0.001 ~ 1.000 |
|
Computation |
W / (V x A) =
Power Factor (PF) |
|
|
Frequency |
|
Measurement Range |
40Hz ~ 400Hz |
|
Accuracy
(at 23°C+5°C) |
+
0.2% of reading |
|
|
General |
|
Display |
4 digits 0.56" LED
and 2 sets of 4 digits 0.4" LED |
|
Minimum Input |
2% of reading |
|
Response Time |
2 cycles/sec |
|
Overload Indicating |
" O.L " |
|
|
Power Source |
AC 86 ~ 265V,
50/60Hz |
|
|
Accessories |
Instruction manual
× 1,
Power cord × 1 |
| Option:RS-232 or
RS-485 with disk |
|
|
Dimensions & Weight |
251(W) × 91(H) ×
291(D) mm, Approx. 1.6kg |