| DC Voltage |
|
| Range |
200mV, 2V, 20V,
200V, 1000V 5 ranges |
| Accuracy |
+(0.5% rdg
+ 1 digit) |
| Input
Impedance |
10Mohm |
|
| AC Voltage |
|
| Range |
200mV, 2V, 20V,
200V, 750V 5 ranges |
| Accuracy |
40Hz ~ 500Hz?+(1% rdg +
4 digits) on all ranges |
| Input
Impedance |
10Mohm |
|
| DC Current |
|
| Range |
200µA, 2mA, 20mA,
200mA, 2000mA, 20A 6 ranges |
| Accuracy |
200µA ~ 200mA 4
range+(0.5% rdg + 1 digit) |
| 2000mA ~ 20A 2
range+(1% rdg + 3 digits) |
|
| AC Current |
|
| Range |
200µA, 2mA, 20mA,
200mA, 2000mA, 20A 6 ranges |
| Accuracy |
200µA ~ 200mA 4
range |
40Hz ~ 500Hz+(1%
rdg + 4 digits) |
| 2000mA ~ 20A 2
range |
40Hz ~ 500Hz+(1.5%
rdg + 2 digits) |
|
| Resistance |
|
| Range |
200, 2k, 20k,
200k, 2M, 20M 6 ranges |
| Accuracy |
200~ 2M 5 range+(0.75%
rdg + 1 digit) |
|
20MO range+(1.5%
rdg + 5 digits) |
|
| Capacitance |
|
| Range |
2nF, 20nF, 200nF,
2µF, 20µF 5 ranges |
| Accuracy |
+(2% rdg +
4 digits) |
| Test
Frequency |
300Hz +5% |
|
| Diode Test |
|
| Test
Current |
2.5mA maximum |
| Open
Voltage |
3.2V maximum |
|
| Continuity
Beeper |
|
| Description |
Buzzer sounds if
conductance less than 30O |
| Test
Current |
2.5mA maximum |
| Open
Voltage |
3.2V maximum |
|
| Display |
0.5" LCD
display |
|
| Power
Source |
AC 110V/220V +15%,
50/60Hz |
|
| Accessories |
Instruction manual
Power cord
Test lead GTL-107 |
|
| Dimensions
Weight |
9.1"(W) ×
3.7"(H) × 11"(D) Approx. 4.4 lbs. |