DCV |
Maximum Voltage: 1000V Accuracy:
Fluke 83 V: ±(0.1%+1)
Fluke 87 V: ±(0.05%+1)
Maximum Resolution:
Fluke 83 V: 100 µV
Fluke 87 V: 10 µV |
|
ACV |
Maximum Voltage: 1000V
Accuracy:
Fluke 83 V: ±(0.5%+2)
Fluke 87 V: ±(0.7%+2) True RMS
AC Bandwidth Fluke 83 V: 5kHz
Fluke 87 V: 20kHz*
*with low pass filter; 3db @ 1kHz
Maximum Resolution: 0.1 mV |
|
DC
Current |
Maximum Amps: 10A Amps Accuracy: Fluke 83 V: ±(0.4%+2)
Fluke 87 V: ±(0.2%+2)
Maximum Resolution: Fluke 83 V: 0.01 mA
Fluke 87 V: 0.01 µA |
|
AC
Current |
Maximum Amps: 10A Amps Accuracy: Fluke 83 V: ±(1.2%+2)
Fluke 87 V: ±(1.0%+2) True RMS
Maximum Resolution: 0.1 µA |
|
Resistance |
Maximum Resistance: 50 MW Accuracy: Fluke 83 V: ±(0.4%+1)
Fluke 87 V: ±(0.2%+1)
Maximum Resolution: 0.1W
|
|
Capacitance |
Maximum Capacitance: 9,999 µF
Accuracy: ±(1%+2)
Maximum Resolution: 0.01 nF |
|
Frequency |
Maximum Frequency: 200 KHz
Accuracy: ±(0.005%+1)
Maximum Resolution: 0.01 Hz |
|
Duty
Cycle |
Maximum Duty Cycle: 99.9 %
Accuracy: ±(0.2 per KHz +0.1%)
Maximum Resolution: 0.1 % |
|
Temperature Measurement |
87 V, 87
V/E
-200.0°C - 1090°C
-328.0°F - 1994.0°F, 1.0% excluding probe |
|
80 BK
Temperature Probe |
-40 °C -
260 °C
-40 °F - 500 °F, 2.2 °C or 2% whichever is greater |
|
Conductance |
Maximum Conductance: 60.00 nS
Accuracy: ±(1.0%+10)
Maximum Resolution: 0.01 nS |
|
Operating Range |
Operating Temperature: -20 °C - 55 °C
Storage Temperature: -40 °C - 60 °C |
|
Physical |
5.2 cm x
9.8cm x 20.1 cm (2.06” x 3.86” x 7.93”)
624 g (22 oz.) |
|
Included Accessories |
87V
and 83V; TL75 test leads, AC72 Alligator Clips, Holster, 9V battery
(installed), Getting Started Manual, and CD with detailed manual. 87V
includes an 80BK temperature probe.
87V/E; 87V, TL224 silicone test leads, AC220 long reach
alligator clips, TP238 test probes, magnet and strap, 80BK temperature
probe, holster, 9V battery (installed), Getting Started Manual, and CD
with detailed manual |