Backlit display for use in poorly lit areas
Fluke 61     Yes
Fluke 65   Yes
Fluke 62   Yes
Fluke 63   Yes
Fluke 66   Yes
Fluke 68   Yes
 
Holds temperature readings
Fluke 61     Yes
Fluke 65   Yes
Fluke 62   Yes
Fluke 63   Yes
Fluke 66   Yes
Fluke 68   Yes
Range
Fluke 61 -18 to 275 ºC (-0 to 525 ºF)
Fluke 65 -40 to 500 ºC (-40 to 932 ºF)
Fluke 62 -30 to 500 ºC (-20º to 932 ºF)
Fluke 63 -32 to 545 ºC (-25 to 999 ºF)
Fluke 66 -32 to 600 ºC (-25 to 1100 ºF)
Fluke 68 -32 to 760 ºC (-25 to 1400 ºF)
MIN/MAX/AVG
Fluke 61    N/A
Fluke 65     MIN/MAX
Fluke 62    MAX
Fluke 63    MAX
Fluke 66    All
Fluke 68    All
Datalogging
Fluke 61    N/A
Fluke 65    N/A
Fluke 62    N/A
Fluke 63    N/A
Fluke 66   Yes
Fluke 68    Yes
Distance to spot ratio
Fluke 61     8:1
Fluke 65     8:1
Fluke 62    10:1 at 80% energy
Fluke 63    12:1
Fluke 66    30:1
Fluke 68    50:1
Hi-Lo Alarm
Fluke 61      N/A
Fluke 65       N/A
Fluke 62       N/A
Fluke 63      Yes
Fluke 66      Yes
Fluke 68      Yes
Optional RTD probe (contact temperature measurement)
Fluke 61   N/A
Fluke 65   N/A
Fluke 62   N/A
Fluke 63   N/A
Fluke 66  Yes
Fluke 68   Yes
Emissivity
Fluke 61   Fixed at 0.95
Fluke 65   Fixed at 0.95
Fluke 62   Fixed at 0.95
Fluke 63    Fixed at 0.95
Fluke 66   Digitally adjustable (from 0.1 to 1.0 by 0.01)
Fluke 68   Digitally adjustable (from 0.1 to 1.0 by 0.01)

Measurement Accuracy
Fluke 61
-18 °C (0 °F) to -1 °C (30 °F) ± 3 °C (5 °F)
above -1 °C (30 °F) to 275 °C (525 °F) ± 2% of reading or 2 °C (3.5 °F)
  (With the instrument stable between 23-25 °C)
Fluke 65
Above 0 ºC (32 ºF) : ± 2 ºC (± 4 ºF)
Below 0 ºC (32 ºF) : ± 5 ºC (± 9 ºF)
  (With instrument stable at 23ºC ± 3 ºC)
Fluke 62
10 ºC to 30 ºC (50 ºF to 86 ºF): ± 1 ºC (2 ºF)
Outside 10 ºC to 30 ºC (50 ºF to 86 ºF): ± 1.5 ºC (3 ºF) or ± 1.5 % of reading, whichever is greater
Fluke 63, 66, 68
-32 to -26 ºC (-25 to -15 ºF): ±3 ºC (±5 ºF)
-26 to -18 ºC (-15 to 0 ºF): ±2.5 ºC (±4 ºF)
-18 to 23 ºC (-0 to 73 ºF): ±2 ºC (±3 ºF)
  For targets above 23 ºC (73 ºF): ±1% of reading or ±1 ºC (±2 ºF), whichever is greater

 

 