| Technical Data |
| Inputs |
| Number: |
4 voltage and current (3
phases + neutral) |
| Maximum voltage: |
1000 Vrms (6 kV peak) |
| Maximum sampling
speed: |
200 kS/s on each channel
simultaneously |
|
| Volt/Amps/Hertz |
| Vrms (AC +
DC) |
|
|
Measurement range: |
1 ... 1000 V |
| Accuracy: |
0.1% of Vnom |
|
|
| Vpeak |
|
|
Measurement range: |
1 ... 1400 V |
| Accuracy: |
5% of Vnom |
|
|
| Crest
factor, voltage |
|
|
Measurement range: |
1.0 ... >
2.8 |
| Accuracy: |
±5% |
|
|
| Arms (AC +
DC) |
|
|
Measurement range: |
0 ... 20 kA |
| Accuracy: |
±0.5% ± 5
counts |
|
|
| Apeak |
|
|
Measurement range: |
0 ... 5.5 kA |
| Accuracy: |
5% |
|
|
| Crest
factor, A |
|
|
Measurement range: |
1 ... 10 |
| Accuracy: |
±5% |
|
|
| Hz 50 Hz
nominal |
|
|
Measurement range: |
42.50 ...
57.50 Hz |
| Accuracy: |
±0.01 Hz |
|
| Dips and swells |
| Vrms (AC+DC)
² |
|
|
Measurement range: |
0.0% … 100%
of Vnom |
| Accuracy: |
±0.2% of
nominal voltage |
|
|
| Arms (AC+DC)
² |
|
|
Measurement range: |
0 ... 20 kA
|
| Accuracy: |
±1% ± 5
counts |
|
| Harmonics |
| Harmonic (interharmonic)
(n) |
|
|
Measurement range: |
DC, 1..50;
(Off, 1..49) measured according to IEC 61000-4-7 |
|
|
| Vrms |
|
|
Measurement range: |
0.0 … 1000 V |
| Accuracy: |
±0.05% of
nominal voltage |
|
|
| Arms |
|
|
Measurement range: |
0.0 … 4000
mV x clamp scaling |
| Accuracy: |
±5% ± 5
counts |
|
|
| Watts |
|
|
Measurement range: |
Depends on
clamp scaling and voltage |
| Accuracy: |
±5% ± n x 2%
or reading, ± 10 counts |
|
|
| DC voltage |
|
|
Measurement range: |
0.0 … 1000 V |
| Accuracy: |
±0.2% of
nominal voltage |
|
|
| THD |
|
|
Measurement range: |
0.0 … 100.0% |
| Accuracy: |
±2.5% V and
A (± 5% Watt) |
|
|
| Hz |
|
|
Measurement range: |
0 … 3500 Hz |
| Accuracy: |
± 1 Hz |
|
|
| Phase
angle |
|
|
Measurement range: |
-360º ...
+360º |
| Accuracy: |
± n × 1.5º |
|
| Power and energy |
| Watt, VA,
VAR |
|
|
Measurement range: |
1.0 … 20.00
MVA¹ |
| Accuracy: |
±1% ± counts |
|
|
| kWh, kVAh,
kVARh |
|
|
Measurement range: |
00.00 …200.0
GVAh¹ |
| Accuracy: |
± 1.5% ± 10
counts |
|
|
| Power
Factor/ Cos Ф / DPF |
|
|
Measurement range: |
0…1 |
| Accuracy: |
± 0.03 |
|
| Flicker |
| Pst (1
min), Pst, Plt, PF5 |
|
|
Measurement range: |
0.00 … 20.00 |
| Accuracy: |
±5% |
|
| Unbalance |
| Volts |
|
|
Measurement range: |
0.0 … 5.0% |
| Accuracy: |
±0.5% |
|
|
| Current |
|
|
Measurement range: |
0.0 … 20% |
| Accuracy: |
± 1% |
|
| Transient Capture |
| Volts |
|
|
Measurement range: |
±6000 V |
| Accuracy: |
±2.5% of
Vrms |
| Minimum
detect duration |
5 µs
(200kS/s sampling) |
|
| Inrush mode |
| Arms (AC+DC) |
|
|
Measurement range: |
0.000 …
20.00 kA¹ |
| Accuracy: |
±1% of meas
± 5 counts |
|
|
| Inrush
duration (selectable) |
|
|
Measurement range: |
7.5 s ... 30
min |
| Accuracy: |
±20 ms (Fnom
= 50 Hz) |
|
| Autotrend
recording |
| Sampling: |
5
readings/sec continuous sampling per channel |
| Memory: |
1800 min,
max and avg points for each reading |
| Recording
time: |
Up to 450
days |
| Zoom: |
Up to 12x
horizontal zoom |
|
| Memory |
| Screens & data: |
50, shared memory
divided between logging, screens and data sets |
|
| Notes |
| ¹ |
Depending on clamp
scaling |
| ² |
Value is measured over 1
cycle, commencing at a fundamental zero crossing, and refreshed
each half-cycle |
|