ScopeMeter 190 Series: Speed,
performance and analysis power.
For the more demanding applications, the ScopeMeter 190 Series high-performance oscilloscopes offer specifications usually found on top-end bench instruments. With up to 200 MHz bandwidth, 2.5 GS/s real-time sampling and a deep memory of 27,500 points per input they’re ideal for engineers who need the full capabilities of a high-performance oscilloscope in a handheld, battery powered instrument.
|
|
To Fluke190 Series Medical_Scopemeters®
| Features..... |
|
|
|
|
|
All this power in your hand A choice of bandwidth The ScopeMeter 190C and 190B Series offer up to 200 MHz bandwidth for capturing high-frequency signals found in today’s state-of-the-art electronics. For less demanding applications, there are also 100 MHz and 60 MHz models. You still get the same advanced functionality without paying for bandwidth you don't need. |
See what's really happening
With a maximum real-time sampling rate of 2.5 GS/s per input, you can see what
really happens, with 400 ps resolution. Both inputs have their own digitizer, so
you can simultaneously acquire two waveforms and analyze them with the highest
resolution and detail. If an anomaly flashes by on the screen, just press the
Replay button to see it again. And thanks to the wider screen, you will always
see a 12 divisions time window - giving a far better overview of what's
happening both before and after the trigger event!
Easier
identification of traces, everywhere
The full-color display makes identification of individual waveforms easier,
particularly when displaying large amplitude or multiple overlapping waveforms
on screen. On-screen color labels, measurements and warnings are clearly linked
to specific waveforms. The bright, high-contrast display allows for clear
reading under varying light conditions. And still a 4-hour battery operation
time is assured!
See dynamic signal behavior instantaneously
The Digital Persistence mode (Fluke 190C) helps to find anomalies and to analyze
complex dynamic signals by showing the waveforms amplitude distribution over
time. Digital Persistence uses multiple intensity levels and user selectable
decay time - it's as if you're looking at the display of an analog, real time
oscilloscope! The fast display update rate that's standard on all models reveals
signal changes instantaneously, useful for instance when making adjustments to a
system under test.

Automatic capture and replay of 100 screens
Scope users know how frustrating it is to see an one-time anomaly flash by never
to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in
time with a touch of the replay button. In normal use, the instrument
continuously memorizes the last 100 screens. Each time a new screen is acquired,
the oldest is discarded. At any moment, you can "freeze" the last 100 screens
and scroll through picture-by-picture or replay as a "live" animation. Cursors
can be used for further analysis. You can even use the advanced trigger
capabilities to capture up to 100 specific events. Two sets of 100 captured
screens with individual time stamps can be stored for later recall or download
to a PC.
Plus Much More.....
| Specifications..... |
|
|
|
|
Download
Detailed Spec.
Sheet (.pdf)
![]()
| Summary Specifications | |
| Bandwidth |
Fluke 199C, 199B: 200 MHz Fluke 196C, 196B: 100 MHz Fluke 192B: 60 MHz |
| Max. real time sample rate |
Fluke 199C, 199B: 2.5 GS/s Fluke 196C, 196B: 1.0 GS/s Fluke 192B: 500 MS/s |
| Display |
Fluke 19xC: 144 mm Full Color
LCD Fluke 19xB: 144 mm Monochrome LCD |
| Digital Persistence |
Fluke 19xC: Yes, gives analog
oscilloscope like waveform decay (user selectable) Fluke 19xB: Persistence on/off |
| Envelope mode | Yes |
| Waveform Compare |
Fluke 19xC: Visual Reference and
Automatic ‘Pass / Fail’ testing Fluke 19xB: Visual Reference |
|
Max. record length … in Scope mode: |
1200 points per input channel |
| … in ScopeRecord mode: | 27,000 points per input or more (5 ms/div…2 min/div.) |
| Number of inputs | 2 plus external / DMM input, all isolated from each other and from ground |
| Number of digitizers | 2 |
| Independently floating isolated inputs | Up to 1000 V between inputs, references and ground |
| Input sensitivity |
Fluke 19xC: 2 mV/div. … 100
V/div. Fluke 19xB: 5 mV/div. … 100 V/div. |
| Glitch capture | Up to 3 ns using Pulse Width triggering; 50 ns peak detect at 5 ms/div. to 1 min/div. |
| Timebase range in Scope mode |
Fluke 199C, 199B, 196C, 196B: 5
ns/div to 2 min/div Fluke 192B: 10 ns/div to 2 min/div. |
| Trigger types | Connect-and-View®, Free Run, Single Shot, Edge, Delay, Video Frame, Video line, Selectable pulse width and External |
| Scope Measurements | 7 cursors measurements, 30 automatic measurements |
| Waveform Mathematics | A + B, A – B, A x B, A versus B (X-Y-mode, giving Lissajous diagrams) |
| Scope-Record Trigger modes | Start on Trigger, Stop on Trigger |
| Capture last 100 screens | Automatic, with Replay capability |
| Dual input TrendPlot | Yes, with Cursors and Zoom |
| Memory for screens and set-ups |
10 screens with set-up; 5 more memories are made available upon registration of theScopeMeter |
| Memory for recordings | Two, each can store 100 scope screens, a ScopeRecord or a TrendPlot |
| True RMS multimeter | 5000 counts, Volts, Amps, Ohms, Continuity, Diode, Temp |
| Safety certified (EN61010-1) | 1000 V CAT II / 600 V CAT III (instrument and included accessories) |
| Battery (installed) | 4 hr Ni-MH BP190 |
| Line power | Adapter / battery-charger included |
| Size | 25.6 x 16.9 x 6.4 cm (10.1 x 6.7 x 2.5 inch) |
| Weight | 2 kg |
| PC and Printer interface | Using optional Optically Isolated RS-232 adapter / cable |
| Warranty | 3 years on main instrument, 1 year on the standard accessories |
| Ordering Information..... |
|
|
|
|
| Fluke 192B | 60 MHz. Scopemeter, B/W Display | $2,1450.00 * |
| Fluke 192B/003S | 60 MHz. Scopemeter w/SCC190, B/W Display | $2,580.00 * |
| Fluke 196B | 100 MHz. Scopemeter, B/W Display | $2495.00 * |
| Fluke 196B/003S | 100 MHz. Scopemeter w/SCC190, B/W Display | $2,930.00 * |
| Fluke 199B | 200 MHz. Scopemeter, B/W Display | $2,845.00 * |
| Fluke 199B/003S | 200 MHz. Scopemeter w/SCC190, B/W Display | $3,280.00 * |
| Fluke 196C | 100 MHz. Scopemeter, COLOR Display | $2,845.00 * |
| Fluke 196C/003S | 100 MHz. Scopemeter w/SCC190, COLOR Display | $3,280.00 * |
| Fluke 199C | 200 MHz. Scopemeter, COLOR Display | $3,195.00 * |
| Fluke 199C/003S | 200 MHz. Scopemeter w/SCC190, COLOR Display | $3,630.00 * |
| SCC190 | FlukeView Software - Cable - Carry Case | $435.00 * |
|
|
||
| * When placing your order, be sure to ask for your INTERNET DISCOUNT |