Extended Specifications
Extended Specifications This document is only available on-line. Click here to read the Extended Specifications document.
(.pdf, 50 KB)

 

Basic Specifications
Primary Digital Display 50,000 Count
Analog Display 51 Segment Bargraph
IEC 61010 Rating CAT III - 1000V / CAT IV - 600V
DCV Maximum Voltage: 1000V
Accuracy: ± (0.025%)
Maximum Resolution: 0.001 mV
ACV (Trms) Maximum Voltage: 1000V
Accuracy: ± (0.4%)
Maximum Resolution: 0.001 mV
DC Current Maximum Current: 10A
Accuracy: ± (0.15%)
Maximum Resolution: 0.01 µA
AC Current (Trms) Maximum Current: 10A
Accuracy: ± (0.75%)
Maximum Resolution: 0.01 µA
Resistance Maximum Resistance: 500 MW
Accuracy: ± (0.05%)
Maximum Resolution: 0.01W
Capacitance 0.01 nF - 50,000 µF
Frequency 0.5 Hz to 1000 kHz
Temperature in ºC and ºF (using optional K-type thermocouple) -200ºC to 1370ºC

 