Features
-
Large display with backlight
- Insulation test (0.01 MW to 2 GW)
- Insulation test voltages (50 V, 100 V, 250 V, 500 V, 1000
V) for many applications
- Live circuit detection prevents insulation test if voltage
> 30 V is detected for added user protection
- Auto-discharge of capacitive voltage for added user
protection
- AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance
(W), Continuity
- Filter for motor drive measurements
(Model 1587)
Capacitance, diode test, temperature, Min/Max, frequency
(Hz)
(Model 1587)
Auto power off to save battery power
CAT III 1000 V, CAT IV 600 V measurement category
Included accessories: Remote probe, test leads and probes,
alligator clips, K-type thermocouple
Accepts optional Fluke TPAK magnetic hanging system to
free your hands for other work
Rugged, utility hard case allows you to bring everything
you need for the job
3-year warranty
|
|
Specifications
|
Voltage DC |
| Maximum
Voltage |
1000 V |
|
Accuracy |
±(0.09%+2) |
| Maximum
Resolution |
0.001V |
|
Voltage AC |
| Maximum
Voltage |
1000 V |
|
Accuracy |
±(2%+3) |
| AC
Bandwidth |
5kHz
with low pass filter; 3db @ 800 Hz |
| Maximum
Resolution |
0.1 mV |
|
Current DC |
| Maximum
Amps |
400mA |
| Amps
Accuracy |
±(0.2%+2) |
| Maximum
Resolution |
0.01 mA |
|
Current AC |
| Maximum
Amps |
400mA |
| Amps
Accuracy |
±(1.5%+2) 1kHz bandwidth |
| Maximum
Resolution |
0.01 mA |
|
Resistance |
| Maximum
Resistance |
50 MΩ |
|
Accuracy |
±(0.9%+2) |
| Maximum
Resolution |
0.1Ω |
|
Capacitance (Model 1587) |
| Maximum
Capacitance |
9,999 μF |
|
Accuracy |
±(1.2%+2) |
| Maximum
Resolution |
1 nF |
|
Frequency (Model 1587) |
| Maximum
Frequency |
100 kHz |
|
Accuracy |
±(0.1%+1) |
| Maximum
Resolution |
0.01 Hz |
|
Temperature Measurement (Model 1587) |
-40.0 °C
to 537 °C
-40.0 °F to 998 °F excluding probe |
|
Diode Test (Model 1587) |
| Range |
6 V |
|
Resolution |
1 mV |
|
Accuracy |
±(2 % +
1) |
|
Insulation Test |
| Minimum
Test Current @ 1kΩ/V |
1mA |
| Test
Voltages |
50, 100,
250, 500, 1000 V |
| Maximum
Resistance per Test Voltage |
100V: 2
GΩ |
| Maximum
Resolution per Test Voltage |
50V:
0.01 MΩ
100V: 0.01 MΩ
250V: 0.1 MΩ
500V: 0.1 MΩ
100V: 0.1 MΩ |
|
Accuracy per Test Voltage |
50V: ±(3
% + 5)
100V: ±(3 % + 5)
250V: ±(1.5 % + 5)
500V: ±(1.5 % + 5)
100V: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ |
|
Environmental Specifications |
|
Operating temperature |
–20 °C
to +55 °C |
| Storage
temperature |
-40°C to
+60°C |
|
Humidity (Without Condensation) |
0% - 95%
(10 °C – 30 °C)
0% - 75% (30 °C – 40 °C)
0% - 40% (40 °C – 55 °C) |
|
Operating Altitude |
2000 m |
|
Safety Specifications |
|
Overvoltage category |
Complies
with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO.
61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement
CAT III 1000 V and CAT IV 600 V |
| Agency
Approvals |
2000 m
CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III
600 V |
|
Mechanical & General Specifications |
| Size
|
203 x
100 x 50 mm (with holster) |
| Weight
|
624 g |
|
Warranty |
3 years |
| Battery
life Alkaline |
Meter
use 1000 hours |
|
Insulation test use |
Meter
can perform at least 1000 insulation tests with fresh
alkaline batteries at room temperature. These are standard
tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on
and 25 seconds off. |
| IP
Rating |
IP40 |
|
|
1587 ET Kit Includes :
- Fluke 1587 -Perform insulation tests, plus a
wide-range of DMM tasks with confidence and ease
- Fluke I400- Use with your Fluke 1587 to
accurately measure AC current without breaking the circuit
- Fluke 62- Mini non-contact thermometer - check for hot
spots and measure temperature
- Rugged, utility hard case to carry everything.
|
 |
|
|
1587 MDT Kit Includes :
- Fluke 1587 - Perform insulation tests, plus a
wide-range of DMM tasks with confidence and ease
- Fluke 1400- Use with your Fluke 1587 to accurately
measure AC current without breaking the circuit
- Fluke 9040 - Check the rotation of three phase motors
easily and safely
- Rugged, utility hard case to carry everything.
|
 |
|
|
|