Measurement lines |
Single-phase/two-wires, Single-phase/three-wires,
Three-phase/three-wires, Three-phase/four-wires |
|
Measurement line frequency |
Auto-detect (50Hz/60Hz) |
| Voltage
range |
600.0V
AC |
| Current
ranges |
Manually switch-able from 2 range sets according to Clamp sensor
500.0mA / 5.000A/ 50.00A / 10.00A / 100.0A / 500.0A / 1.000kA / 5.000 kA |
|
Measurement items |
Impulsive voltage quality :
Transient overvoltage (Impulse), RMS voltage quality :
Voltage swell, Voltage dips, Voltage interruption, Power quality
: Frequency, Voltage, Current, Current peak,
Active/Reactive/Apparent power, Power factor (displaced power factor),
Three phase quality : Voltage unbalance ratio, Current
unbalance ratio, Harmonic quality (Up to 50th order) :
Harmonic voltage, Harmonic current, Harmonic power, Harmonic
voltage/current phase angle, Total harmonic voltage distortion, Total
harmonic current distortion (THD-F, THD-R), |
| Interval
settings |
AUTO /
1 / 5 / 10 / 15 / 30 / 60 minutes |
| Maximum
record-able period |
125
Days with internal non-volatile memory of 4MB-stored data will not be
deleted upon power OFF; partition memory into 4 segments for maximum 31
days of recording each |
| Internal
memory |
4 MB |
| PC
Interface |
USB
Ver.2.0 |
| Power
supply |
9418-15
AC ADAPTER or 9459 BATTERY PACK |
|
Dimensions, mass |
128W ×
246 H × 63 D mm, 1.2 kg with battery pack |
|
Accessories |
Voltage
cords 9438-05 (1set), BATTERY PACK 9459
(1), AC ADAPTER 9418-15 (1), USB Cable (1),
Basic PC Software CD-R (1), Carrying Case (1), Strap (1) |
|